Fitted into the pump's hydraulic circuit, this 6L hydraulic accumulator stores oil under a precharged bladder and releases it the moment the circuit needs a burst of flow — most obviously when the S-valve or gate shifts between delivery strokes. Smoothing those peaks keeps the shift crisp and the line pressure steady instead of hammering through the pipework. Two kinds of buyer order it. The first is a workshop with a pump down on site, where the accumulator has stopped holding pressure and the machine cannot go back to work until a correct unit arrives. The second is a planned rebuild, where the hydraulic circuit is open anyway and the accumulator is renewed with the rest of the wear parts so the pump does not come back a few months later. Distributors keeping Putzmeister spares on the shelf order it for the same two reasons — a spare for their own customers, or a line on a rebuild quote.
Key Features
Matched 6.0 L displacement. The stored volume is the one the circuit was designed around, so pressure peaks are absorbed and the valve shift keeps its speed instead of dragging between strokes.
A workshop job, not a rebuild. The bladder comes already seated in its housing with the gas valve fitted, so there is nothing to press in, nothing to re-seal and no chance of nicking a new bladder against a used shell.
Repeatable supply. Every unit is bought against the original reference, so a second order matches the first — same volume, same ports, same finish.
Same mounting and port. It fits the bracket and hydraulic line of the accumulator it replaces, with no adapter and no re-drilled mounting.
Stocked, not made to order. Units are held in our warehouse as a running line, which keeps a breakdown repair off a factory waiting list.
Supply from a hydraulic accumulator manufacturer. We take these units in volume from the production line rather than one at a time, which is how fit and finish stay consistent from one order to the next.
Model Reference & Replacement
The reference on the old accumulator is the one piece of information an order should always carry. It is stamped or printed on the housing and repeated in the pump's parts book, so read it digit by digit before the old unit leaves the workshop — a single wrong digit lands you with an accumulator for a different machine. Volume alone will not identify the part. A 6.0 L accumulator does not interchange with the 4.0 L or 10 L units used elsewhere in the range, and the bladder inside it carries its own reference, separate from the accumulator's. If you are renewing the bladder only, that is a different number and a different job. Where the marking is worn past reading, compare the physical details instead: the volume marking, the port thread and fitting, the type and position of the gas valve, the bolt pattern on the bracket, and the overall diameter and length against a known unit. Photographs of those details usually settle it. The reference is what a hydraulic accumulator manufacturer builds to, which is why it, and not the litre figure, is what an order should carry. Keep the old accumulator until the new one is fitted and running. If a fitting or a hose turns out to be the wrong one, the old unit is the reference you will want in front of you. - Four things decide whether a 6L hydraulic accumulator can go onto a given machine: the stored volume, the port thread and fitting, the gas-valve type and position, and the bracket bolt pattern. Two units can carry the same nominal volume and still not bolt up or seal. - Volume is the first filter, not the whole fit. A 6.0 L unit will not substitute for a 4.0 L accumulator where the pump was built around the smaller volume, and stepping up to 10 L changes how quickly the shift responds and how much oil the circuit pushes per stroke. - The reference on the machine beats the reference on the box. If the parts book for a Schwing, CIFA, SANY, Zoomlion or JUNJIN pump gives a different number, order that number — we list accumulator and bladder parts across those ranges and match by the number rather than by what looks similar on the bench. - The nitrogen precharge belongs to the machine, not to the accumulator. The figure comes from the pump builder for that circuit; charge a correct unit to the wrong pressure and the valve will still shift badly. Take the setting from the manual for the machine in front of you. - When the label has worn past reading, compare physical details instead: port thread and angle, gas-valve type and position, bracket bolt pattern, volume marking, and overall length and diameter measured against a known unit. - Be wary of listings that treat every 6 L accumulator as interchangeable. Housing shape, port direction and gas-valve arrangement differ between pump families even where the litre figure is identical, and the difference only shows up at fitting time. - This is a new aftermarket replacement identified by the original reference, not an OEM-branded accumulator. If your specification calls for a branded unit with the OEM's own warranty, this is the wrong part for that job. - Send the pump make, model and the number off the old unit, plus a photograph of the port and gas valve, and we will check it against our records and tell you plainly if this unit is not the one.
Installation & Commissioning
Park the pump on level ground, stop the engine and release stored hydraulic pressure before opening any line — an accumulator holds oil under gas pressure even with the machine switched off.
Close the shut-off between accumulator and circuit where one is fitted, then drain the line into a clean container and cap the open ends.
Note how the old unit sits — bracket orientation, port direction and gas-valve position — and photograph it before anything is loosened.
Unbolt the old accumulator and keep the mounting hardware, hose and fittings. Check the thread and seat, because a damaged fitting will leak whatever accumulator is on the other end of it.
Mount this 6L hydraulic accumulator for concrete pump circuits on the same bracket, using new port seals rather than the ones that came off, and tighten the fittings to the figure your pump manual gives.
Charge the gas side with dry nitrogen to the precharge pressure specified for your pump model and application, with the circuit unpressurised. Compressed air is not a substitute.
Start the pump at low load, run the valve through a series of shifts and check the port, gas valve and fittings for weeping. Re-check the precharge after the first day of work and again at the next service.
Maintenance & Bladder Checks
Put it on the service schedule. Check the precharge at every major hydraulic service, so a tired accumulator is found in the workshop rather than on site.
Oil at the gas valve. Hydraulic oil weeping from the gas valve usually means the bladder has split and oil has crossed into the gas side; the unit will not hold pressure after that.
A shift that loses its snap. When the accumulator stops supplying its stored volume, the valve shift softens — or starts to slam — and the pump sounds different between strokes.
Knocking between strokes. Pulsing or knocking that was not there before often tracks back to pressure peaks the accumulator used to absorb.
Corrosion on the shell or gas-valve thread. Once the housing is pitted or the thread is damaged, a new bladder will not seal reliably and the complete unit is the sensible replacement.
Keep one on the shelf. For a fleet running several Putzmeister pumps, a spare 6.0 L unit turns a breakdown into a straight swap.
Store it upright and capped. A spare should stay in its packaging with the ports protected, in a dry place, until it is needed.
Specifications
Part type
Complete hydraulic accumulator (bladder type)
Nominal volume
6.0 L
OEM reference
273962001
Machine application
Putzmeister concrete pump hydraulic circuits
Part status
New aftermarket replacement, not a Putzmeister part
Supplied as
Complete assembled unit, ready to install
Quantity
One accumulator per order
Fit check
Confirmed against OEM number or pump model before dispatch
Brand note
Putzmeister is a trademark of its owner; OEM numbers are used for reference only
Ordering, Payment & Delivery
Send the reference from the old accumulator, the pump model and the quantity you need. A photograph of the markings is enough to start if the label is worn.
We check the line against our stock and quote it. Payment is by T/T or L/C.
Dispatch normally takes 3–5 days from receipt of your order.
Worldwide shipping is by FedEx, DHL, EMS or UPS, and most orders arrive 3–7 days after dispatch. Public holidays or events outside our control can add a few days.
We email the carrier name and tracking number as soon as the parcel leaves, and you can follow it on the carrier's website — so check the shipping address and contact details before you confirm the order.
Open and check the unit within 15 days of receipt. If anything is wrong, email us first and we will send you the return address.
Return shipping is paid by the buyer unless the part arrived faulty or damaged. Once the return reaches us and is checked, the refund is processed to your payment account within a few days.
Questions before or after ordering: WhatsApp +86 19545516660 or email joak816@outlook.com.
A catalogue file and a specification sheet for this unit can go out with your quote — ask the sales desk if your project file needs them.
Technical Support & Model Matching
Not sure a part will fit? Send us the OEM number, the machine model or a photo of the part you are replacing, and our technical team will check it against our records and confirm before you order. Founded in 2009, CZIC GROUP supplies construction machinery spares worldwide, with agents in more than 20 countries. We help buyers with part matching, fault diagnosis and installation or commissioning questions, before and after the sale.
FAQ
Is this a Putzmeister accumulator?
No. It is a new aftermarket replacement built to the original reference, not an OEM-branded accumulator. Putzmeister and the OEM number are used only to identify the part it replaces, and the unit itself is supplied and an aftermarket part.
Will this 6L hydraulic accumulator for concrete pump duty fit my machine?
It is built for Putzmeister concrete pump hydraulic circuits that call for the original reference, on truck-mounted and stationary pumps alike. What decides fit is the number on the accumulator being replaced, not the pump's age or body style — if the parts book gives a different number, the volume or the mounting differs and this unit is not the right one.
Can the precharge be checked without removing the accumulator?
Yes. With the pump stopped and the circuit depressurised, the gas pressure can be read at the gas valve and topped up if it is low. If it will not hold the figure your pump manual specifies, the bladder or the gas valve is at fault and the unit needs attention rather than another top-up.
What else should be looked at when the accumulator is replaced?
The shift circuit around it: shift cylinder seals, the control valve and the pressure setting. If the old bladder split, gas can pass into the oil and leave it foamed, so the oil and filter are worth changing at the same time, and mounting bolts and port seals should be renewed rather than reused.
Will it work on another brand of concrete pump?
Treat another brand as a comparison rather than a direct swap. The nominal volume, port thread, gas-valve arrangement and bracket pattern all have to line up with the machine. Send the pump details and the old unit and the fit can be checked before the order is accepted.
You can send money by T/T Or L/C
We have been committed to providing customers with fast, reliable logistics delivery services. Shipping & Tracking We normally dispatch parts within 3–5 days after receiving your order. Once your order ships, we send you the carrier name and tracking number. Most orders ship by FedEx, DHL, EMS or UPS and take 3–7 days to arrive. Holidays or events beyond our control (such as earthquakes or hurricanes) may add a few days. Please make sure your shipping address and contact details are complete and correct. The carrier name and tracking number are in your shipping confirmation email, and you can track the parcel on the carrier's website. Returns & Refunds We offer a 15-day guarantee from receipt of the parts. Please check the parts as soon as they arrive. Before returning anything, contact us by email and we will send you the return address. The buyer pays return shipping unless the parts arrived faulty or damaged. Once we receive the return and confirm there is no problem, we refund you. The refund reaches your payment account within a few days.